Topics – Tesec Inc. https://tesecinc.samurai-web.tokyo World-Class Manufacturer of Automatic Test Equipment Sat, 13 Oct 2018 07:45:26 +0000 en-US hourly 1 https://wordpress.org/?v=6.8.1 Termination of Support for Windows XP https://tesecinc.samurai-web.tokyo/topics/termination-of-support-for-windows-xp/ https://tesecinc.samurai-web.tokyo/topics/termination-of-support-for-windows-xp/#respond Wed, 12 Feb 2014 01:34:17 +0000 https://tesecinc.samurai-web.tokyo/news/?p=61 Announcement for the termination of support for Windows XP Applicable Equipment Applicable date for order acceptance ~2014/3/31 2014/4/1~2016/12/31 2017/1/1~ Handler Purchase of new mainframe Windows XP embedded Windows XP embedded ※  The shipment by Windows 7 is subject to our engineering study Windows 7 * Only 32 bits version applicable Upgrade of existing M/C to […]

The post Termination of Support for Windows XP appeared first on Tesec Inc..

]]>
Announcement for the termination of support for Windows XP

Applicable Equipment Applicable date for order acceptance
~2014/3/31 2014/4/1~2016/12/31 2017/1/1~
Handler Purchase of new mainframe Windows XP embedded Windows XP embedded
※  The shipment by Windows 7 is subject to our engineering study
Windows 7
* Only 32 bits version applicable
Upgrade of existing M/C to Windows 7< Purchase of new PC with additional PCB is required
Tester Purchase of new mainframe Windows 7
* Only 32 bits version applicable
Upgrade of existing
Mainframe to
Windows 7
Purchase of new PC with additional PCB is required

For more detail information, please contact us.

The post Termination of Support for Windows XP appeared first on Tesec Inc..

]]>
https://tesecinc.samurai-web.tokyo/topics/termination-of-support-for-windows-xp/feed/ 0
Temperature Extension to 175℃ for 4330-IH https://tesecinc.samurai-web.tokyo/topics/temperature-extension-to-175%e2%84%83-for-4330-ih/ https://tesecinc.samurai-web.tokyo/topics/temperature-extension-to-175%e2%84%83-for-4330-ih/#respond Mon, 11 Nov 2013 00:53:25 +0000 https://tesecinc.samurai-web.tokyo/news/?p=39 Optional Application for guaranteed temperature extension to 175 °C for 4330-IH 1.General Guaranteed temperature ranged for 4330-IH can be extended from 150°C to 175°C as optional application. 2.Details of change (1) Temperature guarantees range expansion. Item New version Previous version Setting range -55 to 175°C -55 to 150°C   3.Application Item Description< (1) Temperature setting […]

The post Temperature Extension to 175℃ for 4330-IH appeared first on Tesec Inc..

]]>
Optional Application for guaranteed temperature extension to 175 °C for 4330-IH

1.General

Guaranteed temperature ranged for 4330-IH can be extended from 150°C to 175°C as optional application.

2.Details of change

(1) Temperature guarantees range expansion.

Item New version Previous version
Setting range -55 to 175°C -55 to 150°C

 

3Application

Item Description<
(1) Temperature setting range -55 to 175°C
(2) Temperature guarantee range Low temp. -55 to 0°C
High temp. +50 to 150°C (Standard specification)
High temp. +50 to 175°C (Additional specification)
(3) Temperature accuracy Test site ±2°C
(4) Heating time High temp. 50 min (At150°C)
60 min (At 175°C)
Low temp. 50 min (At -55°C) Note : Excluded the dry time.

For more detail information, please contact us.

The post Temperature Extension to 175℃ for 4330-IH appeared first on Tesec Inc..

]]>
https://tesecinc.samurai-web.tokyo/topics/temperature-extension-to-175%e2%84%83-for-4330-ih/feed/ 0
System Software of Windows 7 for 3041-R and 3042-Q https://tesecinc.samurai-web.tokyo/topics/system-software-of-windows-7-for-3041-r-and-3042-q/ https://tesecinc.samurai-web.tokyo/topics/system-software-of-windows-7-for-3041-r-and-3042-q/#respond Tue, 29 Oct 2013 00:42:16 +0000 https://tesecinc.samurai-web.tokyo/news/?p=33 3041-R/3042-Q System Software for Windows 7 (ST4603) 1.General New System Software for 3041-R/3042-Q which is full compliance to Windows 7(ST4603) has been released. Old System Software for present 3041-R/3042-Q (ST4511) was developed for the Windows XP. Since Window XP is no more available in the market, ST4511 had been operated by using XP emulator on […]

The post System Software of Windows 7 for 3041-R and 3042-Q appeared first on Tesec Inc..

]]>
3041-R/3042-Q System Software for Windows 7 (ST4603)

1.General

New System Software for 3041-R/3042-Q which is full compliance to Windows 7(ST4603) has been released.

Old System Software for present 3041-R/3042-Q (ST4511) was developed for the Windows XP. Since Window XP is no more available in the market, ST4511 had been operated by using XP emulator on WINDOWS 7 or using compatible mode (XP SP2) as the counter-measurement. However, depending on the PC model, ST4511 could not be installed and operated.

In order to solve these problems, new System Software (ST4603) is compliance to Net Framework 3.5 which is installed in Windows 7 as standard and became full compliance to Windows 7.

ST4603 becomes standard System Software for 3041-R and 3042-Q.

2. Details of change

ST4603 consists of:

・Control Center (After Ver2.0.0)

・Task Editor (After Ver2.0.0)

・Password Editor (After Ver2.0)

・Password Reset (After Ver2.0)

・Host link Enable/Disable (After Ver2.0)

For more detail information, please contact us.

The post System Software of Windows 7 for 3041-R and 3042-Q appeared first on Tesec Inc..

]]>
https://tesecinc.samurai-web.tokyo/topics/system-software-of-windows-7-for-3041-r-and-3042-q/feed/ 0
Replacement of Control PC for 3041-R and 3042-Q https://tesecinc.samurai-web.tokyo/topics/replacement-of-control-pc-for-3041-r-and-3042-q/ https://tesecinc.samurai-web.tokyo/topics/replacement-of-control-pc-for-3041-r-and-3042-q/#respond Tue, 29 Oct 2013 00:21:00 +0000 https://tesecinc.samurai-web.tokyo/news/?p=30 3041-R & 3042-Q: Control PC change 1.  General Though a Note PC has been used to control 3041-R and 3042Q, it becomes difficult to provide such Lap Top PC with RS232C function for interfacing with tester due to its discontinuation. After the date mentioned in below, the Desk Top PC is the standard PC for […]

The post Replacement of Control PC for 3041-R and 3042-Q appeared first on Tesec Inc..

]]>
3041-R & 3042-Q: Control PC change

1.  General

Though a Note PC has been used to control 3041-R and 3042Q, it becomes difficult to provide such Lap Top PC with RS232C function for interfacing with tester due to its discontinuation.

After the date mentioned in below, the Desk Top PC is the standard PC for 3041-R and 3042-Q.

2.  Details of required PC

Desk top PC (It is same desk top PC used for DC tester)

- Desk top PC by HP Compaq

- Windows 7 Professional

- 32-bit Operating System

For more detail information, please contact us.

The post Replacement of Control PC for 3041-R and 3042-Q appeared first on Tesec Inc..

]]>
https://tesecinc.samurai-web.tokyo/topics/replacement-of-control-pc-for-3041-r-and-3042-q/feed/ 0
Discontinued Power Relay for KT Series https://tesecinc.samurai-web.tokyo/topics/discontinued-power-relay-for-kt-series/ https://tesecinc.samurai-web.tokyo/topics/discontinued-power-relay-for-kt-series/#respond Thu, 26 Sep 2013 23:51:43 +0000 https://tesecinc.samurai-web.tokyo/news/?p=22 KT Series Thermal Resistance Tester: Power Relay Change The production of previous power relay applied for the KT Series Thermal Resistance Tester is discontinued and for replacement please refers to the following information. The production of previous power relay applied for the KT Series Thermal Resistance Tester is discontinued and for replacement please refers to […]

The post Discontinued Power Relay for KT Series appeared first on Tesec Inc..

]]>
KT Series Thermal Resistance Tester: Power Relay Change

The production of previous power relay applied for the KT Series Thermal Resistance Tester
is discontinued and for replacement please refers to the following information.

The production of previous power relay applied for the KT Series Thermal Resistance Tester

is discontinued and for replacement please refers to the following information.

Caution:

This replacement relay is the special only able to apply for KT series, so please do not use for any other products.

1.  Discontinued Relay

Power relay HG2-DC12V (by Panasonic)

2.  Replacement

PT 1220 board with power relay.

Note: Relay adapter PT1221 is required as socket is changed.

3.  Applicable Model

Mainframe 9214-KT 9414-KT 9424-KT 9614-KT 9624-KT 4314-KT 4324-KT 4334-KT
PU 9215-PU 9425-PU 9615-PU 9625-PU
9626-PU
4015-PU 4025-PU 3935-PU

Note: There are some testers that are excluded from this application.

For more detail information, please contact us.

The post Discontinued Power Relay for KT Series appeared first on Tesec Inc..

]]>
https://tesecinc.samurai-web.tokyo/topics/discontinued-power-relay-for-kt-series/feed/ 0
Relocation of TESEC Inc. Head Office https://tesecinc.samurai-web.tokyo/topics/relocation-of-tesec-inc-head-office/ https://tesecinc.samurai-web.tokyo/topics/relocation-of-tesec-inc-head-office/#respond Wed, 02 Jan 2013 23:28:44 +0000 https://tesecinc.samurai-web.tokyo/news/?p=12 TESEC, Inc. Headquarter was moved from Danbury Connecticut to Baldwin Park California as of January 1st, 2013. The new address is as follows: Previous address 201 Kenosia Ave., Danbury CT 06810 New address 14120 Live Oak Ave., Baldwin Park CA 91706 Phone#: 1-626-813-9930 FAX#: 1-626-813-9958 Our sales office which is located Arizona States also moved. […]

The post Relocation of TESEC Inc. Head Office appeared first on Tesec Inc..

]]>
TESEC, Inc. Headquarter was moved from Danbury Connecticut to Baldwin Park California
as of January 1st, 2013. The new address is as follows:

Previous address

201 Kenosia Ave., Danbury CT 06810

New address

14120 Live Oak Ave., Baldwin Park CA 91706
Phone#: 1-626-813-9930
FAX#: 1-626-813-9958

Our sales office which is located Arizona States also moved.

The new address is as follows:

Previous address

15720 N. Greenway-Hayden Loop, Suite 8A, Scottsdale AZ 85260

New address

7339 E. Acoma Drive Suite 2, Scottsdale AZ 85260
Phone#: 1-480-829-6879 (Same as before)
FAX#: 1-480-829-0209 (Same as before)

For more detail information, please contact us.

The post Relocation of TESEC Inc. Head Office appeared first on Tesec Inc..

]]>
https://tesecinc.samurai-web.tokyo/topics/relocation-of-tesec-inc-head-office/feed/ 0